SPLASH™ NfL Singleplex Kit

Ultrasensitive neurofilament light chain (NfL) quantification on a standard qPCR instrument

Measure neurofilament light chain (NfL) in human EDTA plasma and cerebrospinal fluid (CSF) with a benchtop proximity ligation assay. The SPLASH™ NfL Singleplex Kit gives your laboratory a focused assay for academic and biopharma research using compatible qPCR instrumentation. NfL is a protein that helps support nerve cells and can enter blood and spinal fluid when those cells are damaged. 3

Catalogue
TSK-00004
Size
96 reactions
Price
US$1,199

For Research Use Only. Not for use in diagnostic procedures.

Last updated: October 21, 2026 · Scientific review: Robert Lin, PhD, Chief Technology Officer

Peer-reviewed research using SPLASH

Explore the peer-reviewed research supporting SPLASH published in Scientific Reports, co-authored by Taudia scientific advisor Jennifer S. Yokoyama, Professor of Neurology at the UCSF Weill Institute for Neurosciences, and her colleagues. The study describes benchtop qPCR assays for five neurological biomarkers, including NfL, and examines a five-biomarker profiling approach in 69 plasma samples. You can review its experimental methods and research findings when planning your study. 1

High quality data with the easiest ultrasensitive workflow.

Wide dynamic range to quantify your samples

Robust signal to reliably measure absolute concentrations

Best-in-class analytical performance with a workflow easier than ELISA​

What is neurofilament light chain (NfL)?

Neurofilament light chain (NfL) is a structural protein in the neuronal cytoskeleton that is released into biofluids following axonal injury or neuronal degeneration. You may also encounter the spelling NF-L in the literature. Researchers measure NfL in blood and CSF to investigate neuroaxonal injury across neurological conditions. 2, 3

NfL biomarker research initially focused on CSF. In 1996, Rosengren and colleagues reported elevated CSF neurofilament protein in amyotrophic lateral sclerosis (ALS) and other neurodegenerative diseases using an immunoassay. In 2013, Gaiottino and colleagues described a sensitive electrochemiluminescence assay for blood NfL, extending research into a sample type suitable for repeated collection. These developments helped establish the transition from CSF studies to longitudinal blood-based investigations. 2, 3

Subsequent studies connected blood NfL with imaging and disease trajectories. Disanto and colleagues reported associations between serum NfL, MRI lesion activity, and disability in multiple sclerosis in 2017. In 2019, Preische and colleagues linked changes in serum NfL with brain atrophy and clinical progression in dominantly inherited Alzheimer’s disease, including presymptomatic mutation carriers. These findings support studying NfL dynamics alongside imaging and clinical measures. 4, 5

Plasma supports repeated blood collection and studies using archived specimens. CSF offers a complementary compartment for central nervous system research, although collection requires lumbar puncture. NfL can reflect peripheral as well as central nervous system injury. Serum-based literature provides biological context; the analytical data below characterize this kit in EDTA plasma and CSF. 3

In Alzheimer’s disease research, NfL can complement amyloid and phosphorylated tau biomarkers by adding information related to neuronal injury. You can examine NfL alongside MRI, cognitive measures, pTau-217, Aβ42/Aβ40, and GFAP to study different aspects of a cohort’s biology. Consider age and neurological comorbidities when designing comparisons, and interpret longitudinal results within the study population and assay used. 1, 3 to 5

NfL assay sensitivity and analytical performance

Taudia evaluated sensitivity, endogenous sample concentrations, dilution linearity, and spike recovery for the NfL Singleplex Kit. The NfL Data Sheet reports the analytical results below for TSK-00004. The calibration curve uses four-parameter logistic regression (4PL).

Sensitivity and sample requirements
SpecificationReported value
Plasma input and dilution12.5 µL per reaction; 4×
CSF input and dilution2 µL per reaction; 25×
Analytical LLOD in sample buffer0.011 pg/mL
Functional LLOQ in plasma0.10 pg/mL
Functional LLOQ in CSF0.63 pg/mL

According to the NfL Data Sheet, Taudia measured EDTA plasma from 24 apparently healthy donors aged 55 years and older in triplicate. The table reports the mean concentration and the percentage of specimens above fLLOQ for that donor set.

Endogenous NfL, healthy donors aged 55+
MatrixDonorsMean concentrationAbove fLLOQ
EDTA plasman = 2410.78 pg/mL100%

According to the NfL Data Sheet, dilution linearity was assessed in two apparently healthy donor EDTA plasma samples diluted from 4× to 32×. Recovery expresses the measured concentration relative to the expected concentration; parentheses retain the ranges reported in the data sheet.

Dilution linearity, EDTA plasma
DilutionRecovery with reported range
4×86.4% (78.7 to 96.4%)
8×98.5% (94.2 to 106.0%)
16×106.9% (101.7 to 112.3%)
32×108.3% (90.7 to 119%)

How the NfL sensitivity and recovery data were measured

Spike recovery

121.7%

According to the NfL Data Sheet, mean spike recovery was 121.7% across two EDTA plasma samples, each spiked at low and high concentrations within the assay range. Recovery was calculated from the increase over the unspiked sample relative to the spike concentration in sample buffer.

LLOD

0.011 pg/mL

For LLOD, Taudia read 15 sample-buffer replicates against the calibration curve in each of six runs. The per-run threshold was the mean background plus 2.5 standard deviations; the reported LLOD was the median across runs.

LLOQ

0.10 pg/mL plasma

For LLOQ, six replicates of serially diluted standard material were evaluated across six runs. The lowest concentration returning 80 to 120% of its expected value with a CV below 20% defined each run’s LLOQ. Taudia reported the median across runs and multiplied it by the sample dilution factor to obtain fLLOQ.

How SPLASH measures NfL

SPLASH™ stands for Solid Phase Ligation Assay with Single wasH. Antibody-linked DNA probes recognize NfL, and proximity ligation generates an amplifiable DNA signal. Magnetic bead capture and washing remove unbound probes before the ligation and qPCR program. See the SPLASH Singleplex User Guide and NfL Quick Guide.

Explore the SPLASH technology and immuno-PCR workflow for the assay principle.

  1. 1Setup15 minutes
  2. 2Binding2 hours at room temperature, or overnight at 4 °C
  3. 3Wash15 minutes
  4. 4Ligation and qPCRAbout 1 hour
  5. 5AnalysisCq values into TallyPro

Your benchtop workflow comprises sample and standard preparation, a 2-hour room-temperature binding incubation, a wash stage, and an approximately 1-hour ligation and qPCR program. The NfL Quick Guide allocates 15 minutes to setup and 15 minutes to washing, giving approximately 3.5 hours before analysis; overnight binding at 4 °C is an alternative.

Export Cq values from your instrument and use TallyPro analysis software with the NfL template to calculate concentrations in pg/mL. Set the dilution factor to match your samples. You will need compatible plates, a magnetic rack, calibrated pipettes, and the consumables listed in the SPLASH Singleplex User Guide.

Store kit components at 4 °C or −20 °C as specified in the NfL Quick Guide; never freeze the magnetic beads. Review the kit Safety Data Sheets for component-specific handling, protective equipment, and disposal guidance.

Singleplex, duplex or 5-plex: choosing an NfL assay format

Use the singleplex when NfL is your primary analyte or an addition to an existing research panel. Browse the SPLASH biomarker kits catalogue to compare available formats.

The NfL and GFAP Duplex Kit supports paired measurements, while the AD 5-plex panel includes pTau-217, Aβ42, Aβ40, NfL, and GFAP for broader biomarker profiling.

For an analyte outside the catalogue, explore the STEP custom assay development program to discuss developing, validating, and deploying an assay with your team. For this kit, contact hello@taudia.com to discuss sample planning and instrument setup.

Inquire about this kit

Frequently asked questions

What is neurofilament light chain (NfL)?

NfL is a neuronal structural protein studied as a biofluid marker of neuroaxonal injury. It is investigated across neurological conditions and is not specific to Alzheimer’s disease. [2 to 5]

How much plasma does the NfL assay need?

According to the NfL Data Sheet, the assay uses 12.5 µL of EDTA plasma per reaction at 4× dilution. Allow additional specimen volume for replicates and pipetting losses.

Can I measure NfL in CSF?

Yes, the NfL Data Sheet characterizes CSF measurement using 2 µL per reaction at 25× dilution, with an fLLOQ of 0.63 pg/mL. Use the CSF preparation conditions when planning your experiment.

Which qPCR instruments are supported?

The kit is designed for 96-well qPCR instruments with FAM detection and compatible 0.2 mL plates. Downloadable NfL templates cover Opus96 and QuantStudio 1, 3, 5, 6 Flex, 6 Pro, 7 Flex, and 7 Pro configurations. Check your model and plate format against the NfL instrument templates.

What are the detection and quantification limits?

According to the NfL Data Sheet, the analytical LLOD is 0.011 pg/mL in sample buffer, and the plasma fLLOQ is 0.10 pg/mL at 4× dilution. Detection and quantification describe different thresholds; use fLLOQ when interpreting low-concentration quantitative results.

How many samples can I run with one kit?

One kit accommodates 39 study samples in duplicate or 26 in triplicate in a single full-plate run using the NfL Quick Guide layout, including duplicate standards, blanks, and optional CheckPoint controls. Each kit supplies 96 reactions across up to two runs, including wells used for standards, blanks, controls, and replicates. Your study sample capacity therefore depends on the plate layout.

Can I combine NfL results from different assays?

Results from different assays require a bridging assessment before you combine them quantitatively. Antibody recognition, calibrators, and matrix effects can influence concentration values, so a shared pg/mL unit does not establish agreement.

References and assay documents

Reference 1 describes SPLASH research; references 2 to 5 provide independent biological and historical context. The kit is for research use only.

  1. Elder N et al. SPLASH: a benchtop platform for accessible, ultrasensitive quantification of plasma biomarkers in Alzheimer’s disease. Scientific Reports (2026), Article in Press.
  2. Rosengren LE et al. Patients with amyotrophic lateral sclerosis and other neurodegenerative diseases have increased levels of neurofilament protein in CSF. Journal of Neurochemistry (1996);67:2013 to 2018. DOI 10.1046/j.1471-4159.1996.67052013.x.
  3. Gaiottino J et al. Increased neurofilament light chain blood levels in neurodegenerative neurological diseases. PLOS ONE (2013);8:e75091. DOI 10.1371/journal.pone.0075091.
  4. Disanto G et al. Serum neurofilament light: A biomarker of neuronal damage in multiple sclerosis. Annals of Neurology (2017);81:857 to 870. DOI 10.1002/ana.24954.
  5. Preische O et al. Serum neurofilament dynamics predicts neurodegeneration and clinical progression in presymptomatic Alzheimer’s disease. Nature Medicine (2019);25:277 to 283. DOI 10.1038/s41591-018-0304-3.

Not seeing your biomarker?

Contact our team to discuss your biomarker needs!